(011) 4296-2442 / 4290-4424
/
info@inner.com.ar -
Features
- Tap values available: 26/23 dB – 29/23 dB – 32/23 dB.
- Fixed reverse window attenuation 23dB at 5-42MHz.
- SMT technology for superior quality and reliability.
- 3 cable slope values available:26dB, 29dB and 32dB.
- A360 aluminium alloy housing with weather-resistant protective powder coating.
- All F ports meet SCTE IPS-SP-400 standard.
- Pressure test at 15psi for 60 seconds under wáter.
- Blocking capacitor withstands 1kV power surge on F-port.
- AC/RF bypass device and patented 360° 4 prong strong holding force seizure.
- Power passing: 12A, 60/90VAC, 60Hz.
- RFI >100dB.
- High isolation and tap return loss for return path.
- Flatness: ±0.35dB.
- 100% leakage test and signal continuity test before packaging.
Distortion best solution:
1 – Hum modulation at 90VA/10A, 5-10MHz < -60dB, 11-749MHz < -70dB, 750-1000MHz < -60dB
2 – Inter modulation on all F ports < -105dB
3 – 2nd harmonics on all F ports < -110dBSPECIFICATIONS
Model No. RWTS4** Test(-dB) Freq (MHz) 26 29 32 QA TYP QA TYP QA TYP Insertion Loss (IN-OUT) 5-50 0.9 0.4 0.9 0.4 0.9 0.4 51-450 1.3 0.6 1.3 0.6 1.3 0.6 451-550 1.5 0.4 1.5 0.4 1.5 0.4 551-750 1.7 1.0 1.7 1.1 1.7 1.0 751-870 1.8 1.3 1.8 1.3 1.8 1.2 870-1000 2.1 1.4 2.1 1.5 2.1 1.3 Tap Loss (IN-OUT)
5-42 22.7 ± 1.5 22.5 22.7 ± 1.5 23.1 23.7 ± 2.5 24.4 43-50 25.2 22.8 26.2 23.8 26.7 25.8 51-100 25.7 23.1 27.7 24.4 28.2 26.7 101-300 26.2 24.3 29.7 26.0 31.2 29.3 301-1000 25.7 ± 1.5 25.5 27.7 ± 2.0 27.4 31.2 ± 3.0 31.2 Isolation
(OUT-TAP)5-1000 26 40 26 42 26 45 Isolation (TAP-TAP)
55-10 18 32 18 29 18 28 11-1000 20 28 20 26 20 30 Return Loss
(ALL)5-10 17 27 17 26 17 26 11-860 17 26 17 26 17 26 861-1000 16 26 16 25 16 25